Customization: | Available |
---|---|
After-sales Service: | Yes |
Warranty: | 5 Years |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Models
|
30K
|
40K
|
50K
|
Input DC (PV side)
|
|||
Recommended max. PV array size
|
60 kW
|
80 kW
|
100 kW
|
Max. usable PV input power
|
60 kW
|
80 kW
|
96 kW
|
Max. input voltage
|
1000 V
|
||
Rated voltage
|
600 V
|
||
Start-up voltage
|
180 V
|
||
MPPT voltage range
|
150-850 V
|
||
Max. input current
|
3*40 A
|
4*40 A
|
|
Max. short circuit current
|
3*60 A
|
4*60 A
|
|
MPPT number/Max. input strings number
|
3/6
|
4/8
|
|
Battery
|
|||
Battery type
|
Li-ion
|
||
Battery voltage range
|
150-800 V
|
||
Max. charge / discharge power
|
33 kW
|
44 kW
|
55 kW
|
Max. charge / discharge current
|
70 A*2
|
||
No. of battery inputs
|
2
|
||
Max. charge / discharge power of each input
|
33 kW
|
44 kW
|
55 kW
|
Communication
|
CAN/RS485
|
||
Output AC (Grid side)
|
|||
Rated output power
|
30 kW
|
40 kW
|
50 kW
|
Max. apparent output power
|
30 kVA
|
40 kVA
|
50 kVA
|
Rated grid voltage
|
3/N/PE, 220 V / 380 V
3/N/PE, 230 V / 400 V
|
||
Rated grid frequency
|
50 Hz / 60 Hz
|
||
Rated grid output current
|
45.6 A / 43.3 A
|
60.8 A / 57.7 A
|
76 A / 72.2 A
|
Max. output current
|
45.6 A / 43.3 A
|
60.8 A / 57.7 A
|
76 A / 72.2 A
|
Power factor
|
>0.99 (0.8 leading - 0.8 lagging)
|
||
THDi
|
< 3%
|
||
Input AC (Grid side)
|
|||
Max. AC passthrough current
|
91.2 A / 86.6 A
|
121.6 A / 115.4 A
|
152 A / 144.4 A
|
Rated input voltage
|
3/N/PE, 220 V / 380 V 3/N/PE, 230 V / 400 V
|
||
Rated input frequency
|
50 Hz / 60 Hz
|
||
Input Generator
|
|||
Max. input power
|
30 kW
|
40 kW
|
50 kW
|
Rated input current
|
45.6 A / 43.3 A
|
60.8 A / 57.7 A
|
76 A / 72.2 A
|
Rated input voltage
|
3/N/PE, 220 V / 380 V 3/N/PE, 230 V / 400 V
|
||
Rated input frequency
|
50 Hz / 60 Hz
|
||
Output AC (Back-up)
|
|||
Rated output power
|
30 kW
|
40 kW
|
50 kW
|
Max. apparent output power
|
1.6 times of rated power, 2 s
|
||
Back-up switch time
|
< 10 ms
|
||
Rated output voltage
|
3/N/PE, 220 V / 380 V 3/N/PE, 230 V / 400 V
|
||
Rated frequency
|
50 Hz / 60 Hz
|
||
Rated output current
|
45.6 A / 43.3 A
|
60.8 A / 57.7 A
|
76 A / 72.2 A
|
Efficiency
|
|||
Max. efficiency
|
97.8%
|
||
EU efficiency
|
97.4%
|
||
BAT charged by PV Max. efficiency
|
98.5%
|
||
BAT charged/discharged to AC Max. efficiency
|
97.5%
|
||
Protection
|
|||
Anti-islanding protection
|
Yes
|
||
Output over current protection
|
Yes
|
||
Short circuit protection
|
Yes
|
||
Integrated DC switch
|
Yes
|
||
DC reverse-polarity protection
|
Yes
|
||
Surge protection
|
DC Type II / AC Type II
|
||
Integrated AFCI 2.0
|
Optional
|
||
General Data
|
|||
Dimensions (W*H*D)
|
530*880*290 mm
|
||
Weight
|
73 kg
|
||
Topology
|
Transformerless
|
||
Self-consumption (night)
|
<35w
|
||
Operating ambient temperature range
|
-25 ~ +60°C
|
||
Relative humidity
|
0-95%
|
||
Ingress protection
|
IP66
|
||
Cooling concept
|
Intelligent redundant fan-cooling
|
||
Max. operation altitude
|
4000 m
|
||
Grid connection standard
|
G99, VDE-AR-N 4105 / VDE V 0124, EN 50549-1/EN 50549-10, VDE 0126 / UTE C 15/VFR:2019, NTS 631/RD 1699/RD 244 / UNE 206006 / UNE
206007-1, CEI 0-21, C10/11, NRS 097-2-1, TOR, EIFS 2018.2, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, MEA, PEA,PORTARIA Nº 140, DE 21 DE MARÇO DE 2022 |
||
Safety/EMC standard
|
IEC/EN 62109-1/-2, IEC/EN 61000-6-2/-4, EN 55011
|
||
Features
|
|||
PV connection
|
MC4 Quick connection plug
|
||
Battery connection
|
Terminal connector
|
||
AC connection
|
Terminal Block
|
||
Display
|
LED + Bluetooth + APP
|
||
Communication
|
CAN, RS485, Ethernet, Optional: Wi-Fi, Cellular, LAN
|